JAM200
Features
• Active Class 1 and Reactive Class 2
• EMC Proof Design
• Tamper Detection & Anti Fraud
• High Reliability and Long Life
• Comprehensive and Flexible Tariff Structure
• Display & Readout Available Without Power
• Large Digit Display With Backlight
• Active & Reactive Energy in Import and Export
Mode (P+,P-,Q+,Q-)
• Data Readout With Standard OBIS Identifiers
• Internal & External Battery+SuperCap For RTC
Support
• Ability to Withstand 410 V Line Voltage
• Wide Operating Temperature Range
• RTC Accuracy in Comply With IEC 62052-21 ,IEC
62054-21
• 2Years Historical Value for Billing
• Low Battery Alarm with Time Stamp
• Terminal Cover Removal Detection With Historic
Time Stamp
• Save Any Change in Configuration with Operator
ID
|
|
|
Specifications: |
|
General |
|
Meter type |
Static,Singel phase, Active and
Reactive Energy, Bidirectional
|
|
Approval |
IEC
62052-11 ,IEC 62053-21 ,IEC 62052-21
,IEC 62054-21, IEC 62056-61 |
|
Mechanical Compliance |
BS standard |
|
Connection type |
Singel
phase 2 wire |
|
Reference Voltage/frequency
|
220V 230V 240V /
50Hz |
|
Operating voltage range |
150 ... 300V |
|
Over voltage operation |
The meter has been designed to
withstand a voltage of 410V for an
indefinite period |
|
Power consumption |
Voltage circuit: 7.0 VA,
0.6 Watt @ 230 V |
|
Class Index |
Class 1 |
|
Basic Current |
5A |
|
Maximum Current |
100A (permanent) |
|
Class accuracy current range |
Extended from 100 mA up to 120 A |
|
Starting Current
|
≤15mA
|
|
Short Time over current |
3.5 KA for 5 Cycle |
|
Meter Constant |
2000 imp/kWh (Programmable in Test
mode) |
|
Insulation Class |
Double insulation |
|
Communications |
Optical port:lEC 62056-21 Read/Write
Mode C.
Electrical port: CLO, RS232, RS485
(option) for AMR applications |
|
Battery |
Internal long life lithium battery
to support the RTC and Additional
Battery or supercap for R.W.P &
ability to add external battery
easily |
|
Display |
Long life 8 digit LCD (from zero to
nine) & Special Annunciators
Large
digit (8.4mm X 4.2mm) Viewing Angle
±60
Configurable to show 5+ 1,5+2 decimal digits.
Backlight
& Adjustable Contrast of LCD
Data can be displayed in automatic
or manual mode
Programmable data set
and sequence
Ability to show Low battery &
Tampering Event on LCD |
|
None-volatile memory Real |
Retention time more than 40 years
|
|
Time Clock Accuracy |
<±2.5 ppm or 0.25 Sec/day@25°c |
|
Input & Output |
Digital input, SSR output and DBO
(optional) |
|
| |
| Software |
| Registers |
Up to 4 tariff rates (T1 ,T2, .... )and Total active energy (Antifraud) Export active energy (-kWh) and Import Reactive energy (+kvarh) Maximum Demand
for active and reactive energy with time stamp Time and date and three different identification registers for meter Power Reg: voltage, current, PF, active & reactive power, frequency |
| Calendar
|
Support Gregorian & Iranian calendar including correction for leap year and
daylight saving feature |
| Historic registers |
24 sets of historic data for billing registers (for 2 years) |
| 24 sets of historic data for active & reactive Max.Demand
|
| 16 sets of historic data for configuration of meter with operator code |
| 16 sets of historic data for terminal cover removal
|
|
| |
| Technical Specification |
| Tariff structure |
4 tariff rate |
| 8 switching times for each
day |
| 8 day for weeks (7 normal
days and one exclusion date) |
| 30 exception days
|
| 6 weeks for each season |
| 6 seasons for each year
|
| Reserved tariff |
Reserved tariff table can be
preprogrammed for certain date |
| Event recording
|
50 sets of power on and off
with time stamp |
| Number of Maximum demand
reset with time stamp |
| Number of Terminal cover
reset with time stamp |
| Change in configuration with
time stamp & operator code |
| Low Battery alarm with time
stamp |
| Number of max.Demand Exceed
with time stamp |
| Maximum demand |
Maximum Demand windows is
adjustable from 1 to 60 min |
| Test Mode feature |
Ability to change Meter
constant and output pulse and LCD resolution |
| Data Readout Mode |
Readout Mode with standard
OBIS code ACC.To (IEC 620S6-61) |
|
| |
|
Tamper-proof Features |
| Energy Registration |
Measuring absolute value of energy independent of its direction |
| Terminal cover removal |
The meter detects terminal cover opening and record it
|
| Main cover opening |
For opening the main cover, its need to break some part of case |
| Bypass: (optional)
|
Meter monitor phase and null current and detect bypass and record it
|
|
| |
| Climatic and Mechanical |
| Operating temperature range |
-30°C to +65°C
|
| limit temperature range of operation |
-40°C to + 70°C
|
| Storage temperature
|
-40°C to +85°C
|
| Relative humidity
|
Up to 98%
|
| Mean temperature coefficient |
≤ 0.01%@ PF=1 or PF=0.5ind over -40°C to +75°C |
| Degree of protection
|
IPS4
|
| Terminal material
|
Brass and copper
|
| Terminal block material |
Reinforced polycarbonate, non-flammable, recyclable |
| Terminal cover and case material |
Polycarbonate |
| Window material |
Transparent glass polycarbonate
|
| None-repetitive withstand shocks |
>30g,half-sine wave,18msec,in each 6 direction |
| Withstand sinusoidal vibration |
In comply with IEC 60068-2-6 |
| Flammability
|
None-flammable, in comply with 60695-2-11 |
| Meter weight |
450g |
| Dimensions |
173X 130X49 mm |
| Wiring capacity
|
Main cable must be a min.of 25mm2 &max.Of 35mm2 |
|
| |
| EMC -Compatiqility |
| Insulation test |
>5KV,1min,50HZ
|
| Impulse withstand test |
> 12KV 1.2/50µ sec 500 Ω source |
| Fast transient burst (EFT)
|
In comply with IEC 61000-4-4 (±6KV on Line,&Null) |
| Electrostatic Discharge test (ESD ) |
In comply with IEC 61000-4-2 (±15KV Air)
|
| Surge Immunity Test |
In comply with IEC 61000-4-5 (±6.6KV 1.2/50 µ sec 2Ω source) |
| Immunity to electranagnetic RF fields |
In comply with IEC 61000-4-3 (30 V/m) |
| Immunity to conducted |
In comply with IEC 61000-4-6 (10V) |
| RF Conducted & Radiated Emission
|
In comply with CISPR22 Class B
|
|
| |
▲ Top of